Visible Diagnostics Calibration Workshop

Europe/Paris
ITER Council Room (ITER Headquarters)

ITER Council Room

ITER Headquarters

Building 72 Route de Vinon sur Verdon 13115 Saint Paul les Durance FRANCE
Description

The main objective of the workshop is to facilitate the exchange of valuable information between experts and design teams in the field of visible diagnostics calibration and alignment. This collaborative effort is set to play a vital role in the future operation of these systems.
 

The workshop agenda includes the following main areas of discussion:

  • Components calibration and internal alignment at manufacturing;
  • Sub-assembly calibration and alignment at integration in Ports, ISS, PCSS, optical tables, etc;
  • Calibration and alignment during on-site commissioning without plasma;
  • Calibration and alignment during Operations (incl. inter-shots or with standard discharges);
  • In-vessel calibration with the Agile Robot Transporter (ART).
  • Diagnostics commissioning procedures and operational modes.

 

The non-exhaustive list of involved diagnostics is:

  • Spectroscopic systems (E2, E4, E6);
  • Neutral Beam - Plasma interaction spectroscopic systems (E1, EB, EC, EF);
  • Thomson Scat. systems (C1, C2, C4);
  • Visible viewing systems (G1, GA, GE, GL);
  • Inter-pulse operating systems (EA, G8, GC).

 

The workshop will take place in person (favored) but can also be attended remotely (Teams link given below).

    • 10:00 10:15
      Welcome 15m
      Speaker: Maarten De Bock
    • 10:15 10:40
      Factory Acceptance Test - Internal Calibration and Alignment 25m

      Objectives: FAT alignment concepts and required tooling, needs from other PBSes, expected difficulties and risk, how to store and use the calibration data records, etc.

      Speaker: Eiichi Yatsuka
    • 10:40 11:10
      Discussions/exchanges all participants on FAT 30m

      Objectives: clarify the installation sequence and associated tolerances affecting the diagnostic tenant and their alignment strategy.

    • 11:10 11:20
      Coffee Break 10m
    • 11:20 11:50
      Tolerance Chains and alignment strategy 30m

      Objectives: clarify the installation sequence and associated tolerances affecting the diagnostic tenant and their alignment strategy.

      Speaker: Fabien Josseaume
    • 11:50 12:20
      On-site alignment during integration at Port-Integrator Facility or in the Port Cell 30m

      Objectives: how to align optical modules in the PIF, tooling, alignment in the Port Cell, alignment/installation sequence and required inputs from the Port-Integrators, etc.

      Speaker: Charles Barnes
    • 12:20 13:05
      Discussions/exchanges all participants on tolerances and on-site alignment 45m
    • 13:05 13:15
      Recap Day 1 10m
    • 10:00 10:30
      Calibration during integration and on-site commissioning 30m

      Objectives: how to calibrate sub-assemblies during their integration (PIF, PPTF, Port-Cell), Front-to-End calibration (nice-to-have or needed?), tooling (including in the Port-Cell), etc.

      Speaker: Maarten De Bock
    • 10:30 11:10
      Discussions/exchanges all participants on topic 40m

      Discussions/exchanges all participants on topic

    • 11:10 11:20
      Coffee Break 10m
    • 11:20 11:50
      Calibration and alignment during Operations: Back-reflection transmission calibration

      Calibration during active phase of the machine, large focus on back-reflection transmission calibration, back-end instrument calibration, etc.

      Convener: Slim Hamdani
    • 11:50 12:15
      Calibration and alignment during Operations: (High-accuracy) wavelength calibration

      Calibration during active phase of the machine, large focus on back-reflection transmission calibration, back-end instrument calibration, etc.

      Convener: Stanislav Serov
    • 12:15 12:30
      Calibration and alignment during Operations: Back-lighting alignment with Visible cameras

      Calibration during active phase of the machine, large focus on back-reflection transmission calibration, back-end instrument calibration, etc.

      Convener: Jill Foley
    • 12:30 13:00
      Discussions/exchanges all participants on Calibration topic 30m
    • 13:00 13:15
      Recap Day 2 15m
    • 09:00 09:30
      Active Alignment during discharges 30m

      Objectives: Discussion on active alignment during pulses.

      Speaker: Tomohiko Ushiki
    • 09:30 10:00
      Raman Scattering for Thomson Scattering diagnostics 30m

      Discussion on Raman Scattering calibration by the TS expert community.

      Speaker: Rory Scannell
    • 10:00 10:35
      In-vessel Calibration with periodic sources 35m

      Objectives: Discuss potential solutions for in-vessel calibration with the use of sources that are introduced in the machine when the VV is vented. Solutions prior AFP (neutron scaffolding) and post AFP (Agile Robot Transporter) will be discussed.

      Speaker: Stanislav Serov
    • 10:35 11:00
      Discussions/exchanges all participants 25m
    • 11:00 11:10
      Coffee Break 10m
    • 11:10 11:50
      Reference Plasma for Diagnostics Calibration 40m

      Objectives: Discussion on the possibility to have referenced plasmas for diagnostic calibration.

      Speaker: Peter De Vries
    • 11:50 12:15
      Beam into Gas / Beam into Ohmic discharges 25m

      Objectives: Discussion on the possibility to calibrate with beam-into-gas/ohmic discharges in ITER.

      Speaker: Fred Levinton
    • 12:15 13:00
      Close-out discussion and Day 3 Recap 45m